title: "Coolify dashboard unavailable after update"
description: "Resolved · affects Coolify · Oct 10, 2026"
base_url: "https://status.zacklack.de"
canonical: "https://status.zacklack.de/events/report/1"
---

# Coolify dashboard unavailable after update

[Status](/.md) › [Events](/events.md) › Coolify dashboard unavailable after update

Oct 10, 2026 · 2 months ago · affects: Coolify · 18 minutes

## Updates

### + Resolved — Oct 10, 5:40 PM

affects: Coolify (operational)

Coolify access and server metrics were restored. The dashboard and health endpoint returned HTTP 200; Sentinel was healthy and successfully pushing metrics. Existing hosted application containers continued running.

Postmortem — 10 October 2026 (times CEST)

Impact: Coolify's dashboard and control plane were unavailable for approximately 14 minutes, from around 19:22 until verified recovery at 19:36. Server metrics were restored and verified by 19:40. The exact instant HTTP access failed was not measured. Authenticated dashboard workflows and a representative deployment were not independently tested during this recovery.

Cause: Installing Sysbox CE 0.7.1 on 8 October caused Docker 28.5.1 to reload its configuration. A Docker configuration-copy bug corrupted IP address and address-pool values in memory. The running workloads survived, but the upgrade from Coolify 4.3.23 to 4.4.6 exposed the invalid host-gateway address when it recreated Coolify. Docker rejected the container before the application started. Coolify's upgrade script misleadingly reported success despite the startup error. Coolify continued to use the normal runc runtime.

Recovery: A persistent Compose override gave Coolify an explicit gateway mapping. Only Coolify was recreated. Sentinel then required the same mapping workaround, with its credentials, mounts and configuration preserved. The database, Redis, reverse proxy and other application containers retained their original IDs, start times and restart counts. Docker was not restarted.

Remaining work: The outage is recovered, but Docker's runtime address-pool corruption remains. A future automatic Sentinel recreation may encounter the gateway error again. Permanent daemon remediation and a compatible Docker release containing both upstream fixes require planned maintenance. Configuration reloads and future upgrades will need gateway, address-pool and external health checks before being declared successful.

Upstream fixes:
https://github.com/moby/moby/pull/52060
https://github.com/moby/moby/pull/53753

This report and its timeline were entered retrospectively after recovery.

### x Monitoring — Oct 10, 5:36 PM

affects: Coolify (degraded performance)

The Coolify dashboard was healthy and reachable again through both access paths. Its startup also recreated the metrics collector, which hit the same Docker error; metrics recovery was still in progress.

### x Identified — Oct 10, 5:36 PM

affects: Coolify (major outage)

Recovery began with a targeted workaround: replacing Coolify's broken host-gateway mapping with the verified explicit gateway address, then recreating only Coolify. The Docker daemon and other hosted applications were left running.

### x Identified — Oct 10, 5:35 PM

affects: Coolify (major outage)

The cause was traced to a Docker configuration reload during the earlier Sysbox installation. A Docker bug corrupted the host-gateway address, preventing the replacement Coolify container from starting. Existing application containers continued running.

### x Investigating — Oct 10, 5:22 PM

affects: Coolify (major outage)

Retrospective incident record: Coolify became unavailable during the update to 4.4.6. Investigation began after the failed upgrade. Existing hosted services continued running. This timeline was added after recovery; timestamps refer to the recorded incident events.