Z
  • Status
  • Events
  • Monitors
ZL-Media
Overview of our hosted services and their status as well as uptime.
Nov 22, 2026
8 days ago
Berlin location: intermittent connectivity
ber-nas-01ber-gw-01ber-vm-01ber-node-01Quiz - Backend/APIn8nSonarrWizarrSeerrProwlarrJellyfinGoetheMC WebsiteCoolify
Resolved · · November 22 at 12:30 PM (UTC) (11 hours)

The connection has been stable since 04:19 CET, nine hours without another drop, and all monitored services have been reachable throughout. The location received a new public address on each reconnect during the incident, which points to the line repeatedly re-establishing rather than anything running on the hosts. No cause has been confirmed at the provider side yet. A fault report is with the provider, and this incident will be reopened if the connection drops again.

Monitoring · · November 22 at 3:25 AM (UTC)

The connection is back since 04:19 CET. The line came up on a fifth public address in under two hours and the hosted services are reachable again, including the media stack. Monitoring: this incident stays open until the connection has proven stable. It has already recovered twice tonight and dropped again within minutes both times.

Identified · November 22 at 3:03 AM (UTC)

The connection has been completely down since 03:44 CET (02:44 UTC) with no successful reconnect since - the public address has not changed once in that time. Both IPv4 and IPv6 are unreachable and packets stop inside the provider network, so the fault is on the line itself rather than on any host at the location. Reported to the provider; the location stays offline until the line is restored.

Identified · · November 22 at 2:53 AM (UTC)

The location's own host checks are failing too, not just the hosted services, which confirms this is the site connection rather than anything running on it. The Frankfurt and Eygelshoven hosts and everything they serve remain fully available.

Identified · · November 22 at 2:51 AM (UTC)

The Berlin internet connection is dropping and reconnecting in short cycles. Every reconnect assigns a new public address, so access breaks again shortly after it comes back - that is the repeating down and recovered pattern since 01:43. The applications themselves are healthy whenever the line is up. No provider-side fault is published for this area, so we are escalating it as a line fault and will keep monitoring until the connection stabilises.

Investigating · · November 22 at 1:43 AM (UTC)

Services hosted at the Berlin location are intermittently unreachable. Requests to Berlin-hosted websites time out or return a Cloudflare 522 (origin not reachable), and the media services on the Synology host fail with connection timeouts. Services on the Frankfurt and Eygelshoven hosts are unaffected. We are investigating.

Oct 23, 2026
1 month ago
Elevated CPU usage on fra-node-01
fra-node-01
Resolved · · October 23 at 9:43 PM (UTC) (52 minutes)

Monitoring updates are processing normally again, with no further errors observed across several check cycles. CPU usage remains normal. No hosted-service outage was observed.

Monitoring · · October 23 at 9:37 PM (UTC)

The connection fix is deployed. CPU usage is normal, and we are monitoring incoming results.

Identified · · October 23 at 9:22 PM (UTC)

CPU usage is back to normal following mitigation. We are addressing a separate connection issue affecting monitoring updates.

Identified · · October 23 at 8:54 PM (UTC)

The load has been traced to the monitoring database. Monitoring data is partially affected; no hosted-service outage has been observed.

Investigating · · October 23 at 8:51 PM (UTC)

We are investigating elevated CPU usage on fra-node-01 after noticing it in server analytics. Hosted services remain available.

Oct 10, 2026
2 months ago
Coolify dashboard unavailable after update
Coolify
Resolved · · October 10 at 5:40 PM (UTC) (18 minutes)

Coolify access and server metrics were restored. The dashboard and health endpoint returned HTTP 200; Sentinel was healthy and successfully pushing metrics. Existing hosted application containers continued running.

Postmortem — 10 October 2026 (times CEST)

Impact: Coolify's dashboard and control plane were unavailable for approximately 14 minutes, from around 19:22 until verified recovery at 19:36. Server metrics were restored and verified by 19:40. The exact instant HTTP access failed was not measured. Authenticated dashboard workflows and a representative deployment were not independently tested during this recovery.

Cause: Installing Sysbox CE 0.7.1 on 8 October caused Docker 28.5.1 to reload its configuration. A Docker configuration-copy bug corrupted IP address and address-pool values in memory. The running workloads survived, but the upgrade from Coolify 4.3.23 to 4.4.6 exposed the invalid host-gateway address when it recreated Coolify. Docker rejected the container before the application started. Coolify's upgrade script misleadingly reported success despite the startup error. Coolify continued to use the normal runc runtime.

Recovery: A persistent Compose override gave Coolify an explicit gateway mapping. Only Coolify was recreated. Sentinel then required the same mapping workaround, with its credentials, mounts and configuration preserved. The database, Redis, reverse proxy and other application containers retained their original IDs, start times and restart counts. Docker was not restarted.

Remaining work: The outage is recovered, but Docker's runtime address-pool corruption remains. A future automatic Sentinel recreation may encounter the gateway error again. Permanent daemon remediation and a compatible Docker release containing both upstream fixes require planned maintenance. Configuration reloads and future upgrades will need gateway, address-pool and external health checks before being declared successful.

Upstream fixes: https://github.com/moby/moby/pull/52060 https://github.com/moby/moby/pull/53753

This report and its timeline were entered retrospectively after recovery.

Monitoring · · October 10 at 5:36 PM (UTC)

The Coolify dashboard was healthy and reachable again through both access paths. Its startup also recreated the metrics collector, which hit the same Docker error; metrics recovery was still in progress.

Identified · · October 10 at 5:36 PM (UTC)

Recovery began with a targeted workaround: replacing Coolify's broken host-gateway mapping with the verified explicit gateway address, then recreating only Coolify. The Docker daemon and other hosted applications were left running.

Identified · · October 10 at 5:35 PM (UTC)

The cause was traced to a Docker configuration reload during the earlier Sysbox installation. A Docker bug corrupted the host-gateway address, preventing the replacement Coolify container from starting. Existing application containers continued running.

Investigating · · October 10 at 5:22 PM (UTC)

Retrospective incident record: Coolify became unavailable during the update to 4.4.6. Investigation began after the failed upgrade. Existing hosted services continued running. This timeline was added after recovery; timestamps refer to the recorded incident events.